LOW PASS FILTERS ( 87.5 - 108 MHZ )

CODE

INFO

DESCRIPTION

FLP 250   250 W max, N conn., 2nd harmonic atten. > 62 dB, insert. losses < 0.2 dB.
FLP 1500   800 W max, N conn., 2nd harmonic atten. > 62 dB, insert. losses < 0.15 dB.
FLP 3000   2500 W max, LC conn., 2nd harmonic atten. > 62 dB, insert. losses < 0.12 dB.
FLP 8000   6500 W max, 7/8" conn., 2nd harmonic atten. > 62 dB, insert. losses < 0.12 dB.

NOTCH FILTERS

CODE

INFO

DESCRIPTION

FN 78   2nd harm. stop filter (-68 dB), EIA 7/8" conn., 6 kW max, ins. losses < 0.1 dB.
FN 158   2nd harm. stop filter (-68 dB), EIA 1+5/8", 15 kW max, ins. losses < 0.1 dB.

BAND PASS CAVITY FILTERS

CODE

INFO

DESCRIPTION

FC 2X500 Information details linked Two cavity highQ bandpass filter. 87.5-108 MHz. Insert. losses < 0.12 dB. Max pwr: 0.5 kW. In/Out connectors: N (others upon request).
FC 2X1000 Information details linked Two cavity highQ bandpass filter. 87.5-108 MHz. Insert. losses < 0.10 dB. Max pwr: 1 kW. In/Out connectors: LC (others upon request).
FC 2X2000 Information details linked Two cavity highQ bandpass filter. 87.5-108 MHz. Insert. losses < 0.10 dB. Max pwr: 2 kW. In/Out connectors: EIA 7/8" (others upon request).
FC 2X5000 Information details linked Two cavity highQ bandpass filter. 87.5-108 MHz. Insert. losses < 0.10 dB. Max pwr: 5 kW. In/Out connectors: EIA 7/8" (others upon request).
FC 2X10000 Information details linked Two cavity highQ bandpass filter. 87.5-108 MHz. Insert. losses < 0.10 dB. Max pwr: 10 kW. In/Out connectors: EIA 1 5/8" (others upon request).
FC 2X20000 Information details linked Two cavity highQ bandpass filter. 87.5-108 MHz. Insert. losses < 0.10 dB. Max pwr: 20 kW. In/Out connectors: EIA 3 1/8" (others upon request).
FC 2X30000 Information details linked Two cavity highQ bandpass filter. 87.5-108 MHz. Insert. losses < 0.10 dB. Max pwr: 30 kW. In/Out connectors: EIA 3 1/8" (others upon request).
FC 3X500 Information details linked Three cavity highQ bandpass filter. 87.5-108 MHz. Insert. losses < 0.15 dB. Max pwr: 0.5 kW. In/Out connectors: N (others upon request).
FC 3X1000 Information details linked Three cavity highQ bandpass filter. 87.5-108 MHz. Insert. losses < 0.15 dB. Max pwr: 1 kW. In/Out connectors: LC (others upon request).
FC 3X2000 Information details linked Three cavity highQ bandpass filter. 87.5-108 MHz. Insert. losses < 0.15 dB. Max pwr: 2 kW. In/Out connectors: EIA 7/8" (others upon request).
FC 3X5000 Information details linked Three cavity highQ bandpass filter. 87.5-108 MHz. Insert. losses < 0.15 dB. Max pwr: 5 kW. In/Out connectors: EIA 7/8" (others upon request).
FC 3X10000 Information details linked Three cavity highQ bandpass filter. 87.5-108 MHz. Insert. losses < 0.15 dB. Max pwr: 10 kW. In/Out connectors: EIA 1 5/8" (others upon request).
FC 3X20000 Information details linked Three cavity highQ bandpass filter. 87.5-108 MHz. Insert. losses < 0.15 dB. Max pwr: 20 kW. In/Out connectors: EIA 3 1/8" (others upon request).
FC 3X30000 Information details linked Three cavity highQ bandpass filter. 87.5-108 MHz. Insert. losses < 0.15 dB. Max pwr: 30 kW. In/Out connectors: EIA 3 1/8" (others upon request).
FC 1x300   Single cavity highQ bandpass filter. 400-1000 MHz. Insert. losses < 0.18 dB. Max pwr: 300 W. In/Out connectors: N (others upon request).

COMBINING FILTERS ( 87.5 - 108 MHZ ) MORE TRANSMITTERS IN THE SAME ANTENNA - FM

CODE

INFO

DESCRIPTION

FCO S 2x800 Information details linked Two transmitters selective combining filter. 3 dB couplers and cavity system. Max pwr 0.8+0.8 kW. Freq. spacing: > 2 MHz. In/out conn: LC-7/8".
FCO S 2x2000 Information details linked Two transmitters selective combining filter. 3 dB couplers and cavity system. Max pwr 2+2 kW. Freq. spacing: > 2 MHz. In/out conn: 7/8".
FCO S 2x5000 Information details linked Two transmitters selective combining filter. 3 dB couplers and cavity system. Max pwr 5+5 kW. Freq. spacing: > 2 MHz. In/out conn: 7/8"-1+5/8".
FCO 2X500 Information details linked Two transmitters combining filter. Star point and cavity system. Max pwr 0.5+0.5 kW. Freq. spacing: > 2 MHz. In/out conn: N - LC.
FCO 2X1000 Information details linked Two transmitters combining filter. Star point and cavity system. Max pwr 1+1 kW. Freq. spacing: > 2 MHz. In/out conn: LC - EIA 7/8" (others upon request).
FCO 2X2000 Information details linked Two transmitters combining filter. Star point and cavity system. Max pwr 2+2 kW. Freq. spacing: > 2 MHz. In/out conn: EIA 7/8".
FCO 2X5000 Information details linked Two transmitters combining filter. Star point and cavity system. Max pwr 5+5 kW. Freq. spacing: > 2 MHz. In/out conn: EIA 7/8" - EIA 1 5/8.
FCO 2X10000 Information details linked Two transmitters combining filter. Star point and cavity system. Max pwr 10+10 kW. Freq. spacing: > 2 MHz. In/out conn: EIA 1 5/8".
FCO 2X20000 Information details linked Two transmitters combining filter. Star point and cavity system. Max pwr 20+20 kW. Freq. spacing: > 2 MHz. In/out conn: EIA 3 1/8".
FCO 2x30000 Information details linked Two transmitters combining filter. Star point and cavity system. Max pwr 30+30 kW. Freq. spacing: > 2 MHz. Inputt conn: EIA 3 1/8".
FCO 3X500 Information details linked Three transmitters combining filter. Star point and cavity system. Max pwr 3 x 0.5 kW. Freq. spacing: > 3 MHz. In/out conn: N - LC (others upon request).
FCO 3x1000 Information details linked Three transmitters combining filter. Star point and cavity system. Max pwr 1+1+1 kW. Freq. spacing: > 3 MHz. In/out conn: LC - 7/8" (others upon request).
FCO 3x2000 Information details linked Three transmitters combining filter. Star point and cavity system. Max pwr 2+2+2 kW. Freq. spacing: > 3 MHz. In/out conn: EIA 7/8" - EIA 1 5/8".
FCO 3x5000 Information details linked Three transmitters combining filter. Star point and cavity system. Max pwr 5+5+5 kW. Freq. spacing: > 3 MHz. In/out conn: EIA 7/8" - EIA 1 5/8".
FCO 3X10000 Information details linked Three transmitters combining filter. Star point and cavity system. Max pwr 10+10+10 kW. Freq. spacing: > 3 MHz. In/out conn: EIA 1 5/8" - EIA 3 1/8".
FCO 3X20000 Information details linked Three transmitters combining filter. Star point and cavity system. Max pwr 20+20+20 kW. Freq. spacing: > 4 MHz. Input conn: EIA 3 1/8".
FCO 3X30000 Information details linked Three transmitters combining filter. Star point and cavity system. Max pwr 30+30+30 kW. Freq. spacing: > 4 MHz. Input conn: EIA 3 1/8".

COMBINING FILTERS (400 - 1000 MHz) - UHF

CODE

INFO

DESCRIPTION

UCO 2x300 Information details linked Two transmitters combining filter. Star point and cavity system. Max pwr 300+300 W. Freq. spacing: > 16 MHz. In/out conn: N.
UCO 3x300 Information details linked Three transmitters combining filter. Star point and cavity system. Max pwr 300+300+300 W. Freq. spacing: > 18 MHz. In/out conn: N.

DIRECTIONAL COUPLERS

CODE

INFO

DESCRIPTION

FDC 1000   3 dB directional coupler. Max power for each gate: 1 kW. In/out conn.: LC.
FDC 2000   3 dB directional coupler. Max power for each gate: 1.8 kW. In/out conn.: 7/8".
 
ef dw df
1
d 1 1
d 1
1 1
d Exciters d
d Solid State Amplifiers d
d Solid State Transmitters d
d Tube Amplifiers d
d Tube Transmitters d
d DAB Transmitters d
d Remote and Telemetry d
d Microwave Radio Links d
d Coders/Decoders d
d Audio Equipment d
d Radio Link Antennas d
d Transmitting Antennas d
d Antenna Splitters d
d Cable for Antenna Systems d
d Example Antenna Systems d
d • Filters d
d Voltage Regulators d
d Protection Systems d
d Accessories d
     
  Download the complete
FM Products catalog
 
  1  
d 1 1
   
1 1
d d
   
1 1
   
d  
2 surname  
3 email  
3 country  
 
d

 
f d
   
1 1
   
f  
2 surname  
3 email  
3 country  
 
f
 request
d
 
d d d
1 1
1
ITEL S.r.l. Via Friuli, 6 - 33074 Fontanafredda (PN) ITALY - phone +39 0434 997667
VAT ID / P.IVA: 00419270939 Trasparenza Contributi Pubblici
pixel